 CLI300 Series
IRED - Photosensor Photointerrupters
(R)
Clairex
Technologies, Inc.
March, 2005
features * rugged plastic package * hermetically sealed components * various output configurations description The CLI300 series each consist of an IRED and photosensor mounted in a black plastic housing. Each device has 12 inch leads and two holes for bracket mounting in any position. Alternate output circuits and lead lengths are available. For assistance, call Clairex.
absolute maximum ratings (TA = 25C unless otherwise stated) storage and operating temperature................................................ -55C to +100C IRED continuous forward current ............................................................................. 60mA reverse voltage .................................................................................................... 5V continuous power dissipation(1) .................................................................... 100mW CLI325, CLI355 and CLI375 OUTPUT collector-emitter voltage..................................................................................... 30V (2) continuous collector current ......................................................................... 50mA continuous power dissipation(3) .................................................................... 200mW (4) CLI385 OUTPUT supply voltage.................................................................................................... 18V sink current ..................................................................................................... 25mA continuous power dissipation(3) .................................................................... 200mW notes: 1. Derate linearly 1.07mW/C from 25C free air temperature to TA = +100C. 2. 200mA when pulsed at 1.0ms, 10% duty cycle. 3. Derate linearly 2.13mW/C from 25C free air temperature to TA = +100C. 4. Buffer output. Output is LOW when input radiation is below threshold level.
electrical characteristics (TA = 25C unless otherwise noted) symbol parameter Input IRED, all devices
VF IR ID ID VCC ICC Forward voltage Reverse current Collector-emitter dark current Collector-emitter dark current Supply voltage Supply current
min
4 -
typ
-
max
1.5 10 100 50 16 12
units
V A nA nA V mA
test conditions
IF = 10mA VR = 5V VCE = 10V, Ee = 0 VCE = 10V, Ee = 0
Output CLI325, CLI355 Output CLI375 Output CLI385
VCC = 4.5V - 16V
Clairex reserves the right to make changes at any time to improve design and to provide the best possible product.
Revised 3/16/06
Clairex Technologies, Inc. Phone: 972-265-4900
1301 East Plano Parkway Fax: 972-265-4949
Plano, Texas 75074-8524 www.clairex.com
CLI300 Series
IRED - Photosensor Photointerrupters
electrical characteristics (TA = 25C unless otherwise noted) symbol parameter Coupled CLI325
IL VCE(sat) tr, tf VCE(sat) IL VO VOFF tr, tf VCE(sat) IL tr, tf Sensor light current Saturation voltage Output rise and fall time Saturation voltage Sensor light current Voltage output across 270 resistor Voltage output across 270 resistor Output rise and fall time
(R)
Clairex
Technologies, Inc.
min
3.0 12.0 3.2 -
typ
50 300
max
1.2 1.2 0.4 -
units
mA V sec V mA V V sec V mA sec V A mA ns s s
test conditions
IF = 10mA, VCE = 5V IF = 10mA, IC = 4mA IC = 2.0mA, VCC=10V, RL = 100 IF = 10mA, IC = 4mA IF = 10mA, VCC = 5V IF = 10mA, VCC = 5V Ee = 0 IC = 2.0mA, VCC = 10V, RL =100 IF = 20mA, IC = 1mA IF = 10mA, VCE = 5V IC = 2.0mA, VCC = 10V, RL =100 IOL = 15mA, IF = 0(6) IF = 15mA, VOH = 18V
Coupled CLI355
Coupled CLI375
Saturation voltage 0.5 Sensor light current 1.0 Output rise and fall time 5.0 Coupled CLI385 (VCC = 5V unless otherwise noted) VOL Low level output voltage 0.4 IOH High level output leakage 5.0 IF+ IRED positive going threshold(7) 10 IF+/IF Hysteresis ratio 1.2 tr, tf Output rise and fall time 75 tPLH Propagation delay, low to high 6.0 tPHL Propagation delay, high to low 6.0 note: 6. IF = 0 equates to light path being blocked by opaque object. 7. Minimum current applied to IRED to cause output to change state.
IF = 0(6) or 15mA, f = 10kHz, Duty Cycle = 50%, RL = 240, CL = 15pF
Schematic Configurations
RED
CLI325
BLUE
RED
CLI355
BLUE
RED
CLI375
BLUE
RED
CLI385
*
BLUE
GREEN
GREEN 330 ohms
BLACK YELLOW
270 ohms
BLACK YELLOW
BLACK
YELLOW
BLACK
YELLOW
* The CLI385 features an open collector, buffer, digital output. Other output functions such as inverter and
internal 10K pull-up are available. Obtain a copy of the CLL Series data sheet from our website at www.clairex.com to see other available output configurations.
Clairex reserves the right to make changes at any time to improve design and to provide the best possible product
Clairex Technologies, Inc. Phone: 972-265-4900
1301 East Plano Parkway Fax: 972-265-4949
Plano, Texas 75074-8524 www.clairex.com


▲Up To Search▲   

 
Price & Availability of CLI300

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X